Skip to main content

Table 3 Diagnostic test of assessment matrix of PDM-FNA-Fuzzy developed to assist in the diagnosis of breast cancer

From: Fuzzy method for pre-diagnosis of breast cancer from the Fine Needle Aspirate analysis

Diagnostic test Assessment
  GOLD PATTERN DIAGNOSIS  
FUZZY-FNA Malignant (%) Benign (%) TOTAL
Malignant (%) 36.73 9.14 45.87
Benign (%) 0.53 53.60 54.13
TOTAL 37.26 62.74 100.00
Sensitivity = 98.59% Specificity = 85.43%