Skip to main content

Advertisement

Table 4 Quantitative results of validation

From: Identification of dental root canals and their medial line from micro-CT and cone-beam CT records

Description Micro-CT CBCT
Total test image volumes 25 36
Successfully processed image volumes 23 33
Overall success rate 92.0% 91.7%
Overall success in incisors 100.0% 100.0%
Overall success in molars 75.0% 83.3%
Minimum processing time 288 sec 0.69 sec
Average processing time 341 sec 0.93 sec
Maximum processing time 490 sec 1.61 sec