Skip to main content

Table 6 Comparison of modelled standing electrochemical gradients outcomes and the existing empirical data

From: Development of a 3D finite element model of lens microcirculation

Standing fields

3D model radial range

Experimental radial range

3D model averaged

Experimental averaged*

[Na+]i (mMol)

6.9 to 16

5 to 16 1

12.5

13.8 3, 21.5 4

[K+]i (mMol)

91 to 100

Not Measured

95

91.2 5

[Cl-]i (mMol)

10 to 12

Not Measured

11.35

16.8 5, 12.3 5

Ï•i (mV)

−57 to −64

−50 to −70 2

−61.5

−70 6

Ï•e (mV)

0.0 to −27

0 to −36 2

−13.5

−30 6

Pi (kPa)

0.0 to 10

0.0 to 48 7

4.8

Not Measured

  1. References: 1- (Wang et al. 2004) [50]; 2- (Mathias and Rae 1985) [16]; 3- (Delamere and Duncan 1977) [27]; 4- (Duncan 1970) [47]; 5- (Guerschanik et al. 1977) [28]; 6- (Delamere and Paterson 1979) [51]; 7- (Gao et al. 2011) [29].