From: Comparison between mechanical properties of human saphenous vein and umbilical vein
Specimen | Length (mm) | Diameter (mm) | Maximum load in longitudinal tension (N) | Displacement in maximum longitudinal load (mm) | Sample’s width (mm) | Maximum load in circumferential tension (N) | Displacement in maximum circumferential load (mm) |
---|---|---|---|---|---|---|---|
SV 1 | 78 | 4.13 | 24.2 | 28.2 | 10.6 | - | - |
SV 2 | 45 | 4.36 | 31.8 | 12.24 | 11.1 | 21.1 | 3.29 |
SV 3 | 67 | 3.82 | 26.4 | 22.2 | 9.6 | 11.9 | 3.00 |
SV 4 | 35 | 3.92 | 31.4 | 10.16 | 10.5 | 22.7 | 3.53 |
SV 5 | 80 | 3.5 | 19.6 | 28.1 | 10.8 | 17.5 | 3.41 |
UV 1 | 40.5 | 4.17 | 25.5 | 15.2 | 11 | 15.9 | 6.89 |
UV 2 | 45 | 4.52 | 27.4 | 13.6 | 10.6 | 19.1 | 6.76 |
UV 3 | 51 | 3.59 | 16.8 | 15.8 | 10.6 | 11.7 | 4.19 |