Skip to main content

Table 8 Classification results for KDE, SVM and ANN with incorrectly selected wavelet scales to remove baseline wandering

From: Ischemia episode detection in ECG using kernel density estimation, support vector machine and feature selection

 

KDE

SVM

ANN

 

Se.

Sp.

Detect

Trade-off

Se.

Sp.

Detect

Se.

Sp.

Detect

scale 6

0.851

0.785

319

288.2

0.842

0.818

318

0.748

0.864

277.5

scale 7

0.931

0.905

344

232.8

0.932

0.915

349

0.876

0.933

320.7

scale 8

0.939

0.912

349

245.5

0.941

0.923

355

0.875

0.931

319.4

scale 9

0.929

0.906

347

110.4

0.930

0.918

350

0.859

0.918

320.7

scale 10

0.921

0.896

340

97.5

0.916

0.907

343

0.838

0.896

313.2