Skip to main content

Table 3 The FDR value for the feature extraction methods

From: An arrhythmia classification algorithm using a dedicated wavelet adapted to different subjects

Subject

TemplateM

Haar (7)

db6(4)

106CWT

DedicatedW

106

12.781

1.098

5.004

6.409

9.072

116

16.204

3.856

13.851

14.391

30.078

119

30.882

2.279

6.970

11.562

37.488

200

10.937

1.156

6.542

5.853

8.136

201

44.911

0.449

13.613

13.637

37.534

203

6.146

0.005

0.889

0.434

4.080

207

1.818

0.457

1.831

0.659

1.688

208

19.283

2.293

15.109

11.629

32.354

210

5.777

0.780

3.064

2.289

6.236

213

9.592

0.772

5.481

2.986

20.721

214

1.891

0.312

1.378

1.562

5.516

215

13.458

0.088

1.162

1.488

6.338

221

21.050

0.576

8.558

12.860

33.630

223

1.085

1.155

2.156

4.963

4.818

228

7.765

1.372

5.088

8.809

18.488

233

4.094

1.645

3.567

4.624

31.035

Average

12.980

1.143

5.891

6.510

17.951

Std.

11.733

0.997

4.689

4.951

13.604