From: Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System
Source | Model | Values in physiological units |
---|---|---|
Liu et al. [106] | RC | R = 0.89 ~ 1.99 mmHg· s/ml, C = 0.47 ~ 1.86 ml/ mmHg, |
Segers et al. [168] | RLCR2 | R c = 0.035 ~ 0.109 mmHg· s/ml, R = 0.82 ~ 1.15 mmHg· s/ml, C = 0.68 ~ 1.32 ml/ mmHg, L = 0.005 mmHg/(ml·s) |
Stergiopulos et al. [16] | RCR | In vivo measured: R c = 0.058 ~ 0.070 mmHg· s/ml, R = 0.63 ~ 0.79 mmHg· s/ml, C = 1.28 ~ 2.48 ml/ mmHg Data fitted: R c = 0.03 ~ 0.033 mmHg· s/ml, R = 0.63 ~ 0.79 mmHg· s/ml, C = 1.75 ~ 5.16 ml/ mmHg |
Westerhof et al. [13] | RCR | Original values: R c = 90 g/(cm4 s), R = 1200 g/(cm4 s), C = 8 × 10-4 cm4 s2/g Converted into physiological units: R c = 0.0675 mmHg· s/ml, R = 0.9 mmHg· s/ml, C = 1.067 ml/ mmHg |