Skip to main content

Table 3 Quantitative results of AB, AMAS and CaudateCut

From: A fully-automatic caudate nucleus segmentation of brain MRI: Application in volumetric analysis of pediatric attention-deficit/hyperactivity disorder

Database

Method

SI

VO

VD

AD

RMSD

MD

 

AB

79.85

66.55

9.63

0.0029

0.0861

48.31

URNC

AMAS

66.67

51.45

24.81

0.0091

0.0913

48.11

 

CaudateCut

82.60

70.49

9.10

0.0028

0.0780

47.97

 

AB

74.02

58.85

23.34

0.0030

0.0950

30.86

IBSR

AMAS

75.00

60.14

25.54

0.0024

0.0750

28.37

 

CaudateCut

78.91

65.55

17.80

0.0019

0.0687

23.43

  1. Quantitative results of AB, AMAS and CaudateCut methods applied to URNC and IBSR databases. Validation measures are, SI: volumetric similarity index (in %); VO: volumetric overlap (in %); VD: relative absolute volume difference (in %); AD: average symmetric surface distance (in mm); RMSD: root mean square symmetric surface distance (in mm); MD: maximum symmetric surface distance (in mm).